The main reasons of VSWR & Steps to clear this Alarm
Generally the main reasons of VSWR are one of these
1. Feeder connector.
2. Feeder Damages.
3. A faulty Antenna.
Steps to clear the VSWR Alarm
1. Make sure that the jumper is correctly connected in the cabinet.
2. Make sure that the jumper is correctly connected to the feeder.
3. Make sure that the feeder connector is clean with no any damages.
4. Make sure that the feeder is correctly connected to the Antenna Jumper.
5. Make sure that the jumper is correctly connected to the Antenna.
6. if you want it easier, you will perform a DTF " Distance To Fault " test, it will show you the position that causes the VSWR after how many meters.
1. Feeder connector.
2. Feeder Damages.
3. A faulty Antenna.
Steps to clear the VSWR Alarm
1. Make sure that the jumper is correctly connected in the cabinet.
2. Make sure that the jumper is correctly connected to the feeder.
3. Make sure that the feeder connector is clean with no any damages.
4. Make sure that the feeder is correctly connected to the Antenna Jumper.
5. Make sure that the jumper is correctly connected to the Antenna.
6. if you want it easier, you will perform a DTF " Distance To Fault " test, it will show you the position that causes the VSWR after how many meters.